Skip Navigation
Skip to contents

J Trauma Inj : Journal of Trauma and Injury

OPEN ACCESS
SEARCH
Search

Author index

Page Path
HOME > Browse Articles > Author index
Search
Kunwoo Kim 1 Article
Misinterpretation of a skin fold artifact as pneumothorax on the chest x-ray of a trauma patient in Korea: a case report
Yoojin Park, Eun Young Kim, Byungchul Yu, Kunwoo Kim
J Trauma Inj. 2024;37(1):86-88.   Published online February 23, 2024
DOI: https://doi.org/10.20408/jti.2023.0050
  • 505 View
  • 6 Download
AbstractAbstract PDF
Misinterpreting radiographic findings can lead to unnecessary interventions and potential patient harm. The urgency required when responding to the compromised health of trauma patients can increase the likelihood of misinterpreting chest x-rays in critical situations. We present the case report of a trauma patient whose skin fold artifacts were mistaken for pneumothorax on a follow-up chest x-ray, resulting in unnecessary chest tube insertion. We hope to help others differentiate between skin folds and pneumothorax on the chest x-rays of trauma patients by considering factors such as location, shape, sharpness, and vascular markings.
Summary

J Trauma Inj : Journal of Trauma and Injury